Borehole tiltmeter | IF_EFFPI | Geosciences Montpellier | Borehole tiltmeter with optic sensors | IF_EFFPI.pdf | The calibration parameter is the pendulum length | INCLINOMETERS |
Borehole tiltmeter | Lily | Applied Geomechanics | | | | INCLINOMETERS |
Continuous spring relative gravimeter | gphone | Micro-g Lacoste | | | The calibration is computed, either from absolute gravimetry measurements, or from the tide model | GRAVIMETERS |
Continuous superconducting relative gravimeter | iGrav | GWR Instrument | | | The calibration is computed either from absolute gravimetry measurements or from the tide model | SUPERCONDUCTING GRAVIMETER |
CTD | CTD-Diver | Schlumberger | Conductivity Temperature Depth probe | CTD.pdf | | CTD |
Data logger | LBT_LVDT_datalogger | | Datalogger for long-base tiltmeters of La Portalerie | | | |
Electrical sounding | ERT | ImaGeau | Electrical resistivity tomography | | | |
Flux tower | Flux_Tower | | Sonic anemometer : Campbell CSAT3 ; gas analyzer : LICOR LI7500 ; weather station : Campbell ; data acquisition : Campbell CR3000 | | | EDDY CORRELATION DEVICES |
Free-fall absolute gravimeter | FG5 | Micro-g Lacoste | | | Calibration parameters depend on instrument modifications and are porovided by the manufacturer or metrology institutes | GRAVIMETERS |
GNSS | GNSS | x | | | | |
Long base tiltmeter | ILB_EFFPI | Geosciences Montpellier & LAAS-LOSE (Toulouse) | Long-base tiltmeter with optic sensors and interferometer of Fabry-Pérot | ILB_EFFPI.pdf | Data are directly calibrated by the EFFPI software | INCLINOMETERS |
Long base tiltmeter | ILB_LVDT | Geosciences Montpellier | Long base tiltmeter with LVDT sensors | | 4 calibration parameters are measured for each sensor: cst, x, x2 and x3.For each sensor, calibrated value cst + x * value + x2 * value² + x3 * value³ | INCLINOMETERS |
Piezometer | DCX22 | Keller | | dcx22f.pdf | The calibration depends on drift, that is punctually controlled from manual water level measurements | PIEZOMETERS |
Quantum absolute gravimeter | AQG | Muquans | | | | GRAVIMETERS |
Rain gauge | Lora rain gauge | x | Lora rain gauge | | | RAIN GAUGES |
Rain gauge | RG_MAC03 | Primayer | | | The calibration parameter correspond to the conversion factor between the number of counts and the water level | RAIN GAUGES |
Rain gauge | TGP-4901 | Tinytag | | Doc-TINYTAG-plus-2.pdf | The calibration parameter correspond to the conversion factor between the number of counts and the water level | RAIN GAUGES |
Sap flow | Sap flow | INRAE Avignon | | | | |
Seismometer | eSismometer | x | | | | |
Spontaneous Potential | SP | SDEC | https://fr.sdec-france.com/electrodes-impolarisables-pour-la-mesure-de-potentiel-electrique-spontane-pms-9000/ | | | |
Spring relative gravimeter | CG3 | Scintrex | | | Gcal is a punctual calibration computer from relative gravimetry measurements. Other calibration parameters are mesured by the instrument. Calibration aussi pour les données globales sur le causse?? | GRAVIMETERS |
Spring relative gravimeter | CG5 | Scintrex | | | | GRAVIMETERS |